|
|
Home: EcoVantage Catalog: Batteries: UPS/Telecom:
Exide Marathon Front Terminal Cat. No. Exide-MFT Weight 10 lbs | |
Designed for durability in
Telecommunications, and Electric Utility
applications, the GNB FRONT Terminal MARATHONTM
series provides high
performance and reliability in long duration discharge applications.
The location of the terminals on the front (vs. the top) of the battery
greatly facilitates the installation and maintenance of the product
when placed in a cabinet enclosure or on a standard relay rack tray.
The MARATHONTM Front Terminal battery series
highlights another example
of GNB’s extensive experience and world wide leadership in VRLA
technology.
“Designed in” Quality Manufacturing
Quality manufacturing processes for the MARATHONTM
series batteries
incorporate the industry’s most advanced technologies including: an
automated helium leak detection system, a computer controlled “fill by
weight” acid filler, and a temperature controlled water bath formation
process. Each and every unit is capacity tested.
Front Terminal Valve Regulated
Lead Acid Battery for Standby
Power Applications
MARATHON FT Features:
- Patented “Diamond Side-Wall” Design to maintain structural
integrity
in higher operating temperatures
- Durable Flame Retardant Polypropylene Container and Cover
compliant
with UL94 V-0; 28% L.O.I.
- Carry Handles for ease of installation
- High-Compression Absorbent Glass Mat (AGM) Technology for
greater
than 99% recombination efficiency
- Integrated Flash Arrestor ultrasonically welded into cover
for secure
and safe protection
- 10 Year Design Life in float applications @ 25°C
(77°F), 12
year @ 20°C (68°F)
- Superior Lead-Tin-Calcium-Silver Positive Alloy helps to
resist
corrosion
- Higher Vent Opening Pressure to avoid unnecessary gassing.
One-way
self resealing device tested and proven to maximize battery life
- Front Accessible Copper Alloy, 6 mm, Female Terminals for
low
resistance, high integrity connections
- “Easy On\Easy Off”Terminal Post Protector
- Qualifications: IEC 896-2, UL Recognized Component,
Eurobat 10-12
year High Performance
- Footprint Ready for 19" and 23" Relay Rack Applications
Nominal
Voltage:
|
12 Volts |
Nominal
Capacity:
|
90 Amp-Hours; 8 Hour Rate
to
1.75 Volts Per Cell @ 25°C (77°F) |
Alloy:
Positive:
|
Lead, Tin, Calcium, and
Silver |
Negative:
|
Lead Calcium |
Terminal:
|
Front Accessible, Heavy
Duty
Threaded (M6) copper alloy |
Container:
|
I. Reinforced Flame
Retardant
Polypropylene UL94 V-0; 28% L.O. |
Safety
Vent:
|
One-way, self-resealing
vent.
Recessed design accommodates applications requiring central degassing. |
Float
Voltage:
|
2.25 VPC to 2.30 Volt Per
Cell
Range. Recommended 2.27 VPC @ 25°C (77°F) |
Dimensions:
|
15.55" (395 mm) Length x
4.13"
(105 mm) Width x 10.63” (270 mm) Height |
MARATHONTM Specifications
|
Model
Number
|
Voltage |
Capacity (AH)
|
Nominal Dimensions
|
Nominal
Weight
|
8 Hr To 1.75
VCP @ 25oC
|
10
Hr
To 1.80
VPC @ 20oC |
Inches
|
Millimeters
|
A
|
B
|
C
|
A
|
B
|
C
|
lbs
|
kg
|
M12V105FT
|
12
|
104
|
100
|
20.12
|
4.33
|
9.38
|
511
|
110
|
238
|
79
|
35.8
|
M12V125FT
|
12
|
125
|
121
|
22.00
|
4.90
|
11.15
|
599
|
124
|
283
|
105
|
47.6
|
M12V155FT
|
12
|
155
|
150
|
22.00
|
4.90
|
11.15
|
599
|
124
|
283
|
119
|
53.8
|
|
M12V35FT |
12
|
38
|
36.75 |
11.02
|
4.21
|
7.40
|
280
|
107
|
188
|
30.9
|
14
|
| M12V50FT |
12
|
51
|
49.35
|
11.02 |
4.21 |
9.06 |
280
|
107
|
230
|
39.7
|
18
|
| M12V60FT |
12 |
64
|
61.95
|
11.02
|
4.21
|
10.35
|
280
|
107
|
263
|
50.7
|
23
|
| M12V90FT |
12 |
93.9
|
90.30
|
15.55
|
4.13
|
10.63
|
395
|
105
|
270
|
68.4
|
31
|
| M6V200FA |
6 |
218
|
210
|
14.80
|
5.19
|
9.84
|
376
|
131.8
|
250
|
75
|
34
|
Not all battery are listed
|
there is a $600 minium on these
|
|
|